Science Lab Export is a leading Diesel Driven Generator Set 150 KVA at 1500 RPM Manufacturer,and suppliers in India, Diesel Driven Generator Set 150 KVA at 1500 RPM Uruguay (Montevideo), Diesel Driven Generator Set 150 KVA at 1500 RPM Uzbekistan (Tashkent), Diesel Driven Generator Set 150 KVA at 1500 RPM Venezuela (Caracas), Diesel Driven Generator Set 150 KVA at 1500 RPM Vietnam (Hanoi), Diesel Driven Generator Set 150 KVA at 1500 RPM Yemen (Sana'a), Diesel Driven Generator Set 150 KVA at 1500 RPM Zambia (Lusaka), Zimbabwe (Harare), Eswatini (Mbabane) (Lobamba), Ethiopia (Addis Ababa), Fiji (Suva), Gabon (Libreville), Gambia (Banjul), Georgia (Tbilisi), Ghana (Accra), India (Delhi, Mumbai, Kolkatta, Chennai), Indonesia (Jakarta), Iraq (Baghdad), Ivory Coast (Yamoussoukro), Jamaica (Kingston), Jordan (Amman), Kazakhstan (Astana), Kenya (Nairobi), Kiribati (Tarawa), Kosovo (Pristina), Kuwait (Kuwait City), Kyrgyzstan (Bishkek), Laos (Vientiane), Latvia (Riga), Lebanon (Beirut), Lesotho (Maseru), Liberia (Monrovia), Libya (Tripoli), Lithuania (Vilnuis), Luxembourg (Luxembourg), Malawi (Lilongwe), Malaysia (Federal Territory of Kuala Lumpur), Maldives (Malle), Mali (Federal Territory of Kuala Lumpur), Malta (Male), Mauritania (Nouakchott), Mauritius (Port Louis), Mexico (Mexico City), Mongolia (Ulaanbaatar), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cambodia (Phnom Penh), Cameroon (Yaoundé), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb), Cuba (Havana), Cyprus (Nicosia), Czech Republic (Prague), Denmark (Copenhagen) ,Djibouti (Djibouti City), Dominican Republic (Santo Domingo), DR Congo (Kinshasa), Ecuador (Quito), Egypt (Cairo), El Salvador (San Salvador), Equatorial Guinea (Malabo), Eritrea (Asmara), Estonia (Tallinn)

Environmental conditions:
The rated power of the generator is based on the following environmental conditions:
(The country office should provide the actual local conditions to enable the calculation of de-rating that fits those local conditions)
Altitude: at 150m above sea level
Average yearly temperature 30°C
Average 24 hours temperature 40°C
Minimum temperature -10°C
Maximum operating temperature 55°C
Dust storms are expected

General Description:
Diesel driven generator set, water cooled and skid mounted, capable of delivering up to 150kVA at 1500rpm
A complete diesel generator set including the diesel engine, alternator, control panel, automatic starting equipment, fuel tank and all other accessories for autonomous operation

Panel board:
Made of steel sheets of appropriate thickness subjected to anti-oxidizing treatment and covered with epoxy resin with suitable protection factor

The panel board comprises:
Automatic main circuit breaker
Change over switch with positions for "MAINS" - "OFF" - "GENERATOR"
Key to start and stop the unit
Emergency stop button
Set-point for speed/governor control
Set-point for voltage control
Meters for: Volts (with selector switch to show phases to zero, and phase to phase voltages), amperes (three meters or with selector switch to show current in all three phases), frequency, running hours counter
Acoustic and visible alarms for critical parameters including high engine temperature low oil pressure and low fuel should be provided

Engine:
Heavy duty diesel engine, with the following characteristics:
Water-cooled with fresh water loop and tropical radiator
Synchronous speed: Up to 1500rpm
Mechanical speed governor
Heavy duty air cartridge filter
Cartridge oil filter
External fuel filter
Industrial silencer
Exhaust with suitable flexible piping
Automatic electric starter including batteries, leads and automatic battery charging equipment

Fuel tank:
Fuel tank of suitable construction with capacity sufficient to run the generator set continuously for 8 hours at the rated capacity
Suitable piping should be provided for connecting the tank to the engine as well as for filling the tank
Fuel level indicator should be placed conveniently on the panel board

Alternator:
Synchronous and brushless
Automatic fast voltage regulator, maintaining the output within 2% under normal conditions
Screen protected
CEE Sockets: one 3 pole and one 5 pole

Protection:
The generator set should be equipped with automatic shutdown equipment if fatal parameters are exceeded including low oil pressure, high engine temperature and over-speed

Mounting:
The engine and the alternator should be connected with a heavy-duty elastic coupling and should be mounted on a common rigid base frame with anti-vibration dampers and lifting eyes flexible for transportation
Engine, alternator and panel should be one integrated unit mounted on skids

Connection to ground:
The generator is supplied with connection to ground system comprising low resistance rod(s), terminals, cables, etc

   