Pulse oximeter, spot-check Manufacturer,Supplier and Exporter in India

Product Code : EL-RC-11854
Science Lab Export is a leading Pulse oximeter, spot-check Manufacturer,and suppliers in India, Pulse oximeter, spot-check Uruguay (Montevideo), Pulse oximeter, spot-check Uzbekistan (Tashkent), Pulse oximeter, spot-check Venezuela (Caracas), Pulse oximeter, spot-check Vietnam (Hanoi), Pulse oximeter, spot-check Yemen (Sana'a), Pulse oximeter, spot-check Zambia (Lusaka), Zimbabwe (Harare), Eswatini (Mbabane) (Lobamba), Ethiopia (Addis Ababa), Fiji (Suva), Gabon (Libreville), Gambia (Banjul), Georgia (Tbilisi), Ghana (Accra), India (Delhi, Mumbai, Kolkatta, Chennai), Indonesia (Jakarta), Iraq (Baghdad), Ivory Coast (Yamoussoukro), Jamaica (Kingston), Jordan (Amman), Kazakhstan (Astana), Kenya (Nairobi), Kiribati (Tarawa), Kosovo (Pristina), Kuwait (Kuwait City), Kyrgyzstan (Bishkek), Laos (Vientiane), Latvia (Riga), Lebanon (Beirut), Lesotho (Maseru), Liberia (Monrovia), Libya (Tripoli), Lithuania (Vilnuis), Luxembourg (Luxembourg), Malawi (Lilongwe), Malaysia (Federal Territory of Kuala Lumpur), Maldives (Malle), Mali (Federal Territory of Kuala Lumpur), Malta (Male), Mauritania (Nouakchott), Mauritius (Port Louis), Mexico (Mexico City), Mongolia (Ulaanbaatar), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cambodia (Phnom Penh), Cameroon (Yaoundé), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb), Cuba (Havana), Cyprus (Nicosia), Czech Republic (Prague), Denmark (Copenhagen) ,Djibouti (Djibouti City), Dominican Republic (Santo Domingo), DR Congo (Kinshasa), Ecuador (Quito), Egypt (Cairo), El Salvador (San Salvador), Equatorial Guinea (Malabo), Eritrea (Asmara), Estonia (Tallinn)

Pulse oximeter, spot-check, with accessories

Description :
Robust shock resistant design allow use in demanding environments
Suitable for professional clinical use, all patient categories neonate, infant, adult
Power requirements two 1.5V AAA batteries
Batteries must allow at least 2500 spot-checks, calculated at 30 seconds per spot-check, or at least 21 hours of operation.
The unit is equipped with an automatic power off feature.
Ultra-compact pulse oximeter integrated into finger/toe clip
Accommodates finger/toe thicknesses 8 to 25mm directly or through the use of a separate sensor which can be connected to the device.
Spot-check of arterial blood oxygen saturation (SpO2) and heart rate(HR)

Measuring ranges :
SpO2 detection within the range of : 70 to 99%
SpO2 resolution : 1% or less
SpO2 accuracy within : +/-3%
Pulse rate detection : 30 to 240 bpm
Pulse rate resolution : 1 bpm)
Pulse rate accuracy : within: +/-3%
Display shows SpO2, pulse rate, signal strength, sensor error or disconnect and low battery.
Suitable for cleaning and disinfection with hospital-grade cleaning products.v

   