Pulse oximeter, handheld Manufacturer,Supplier and Exporter in India

Product Code : EL-RC-11859
Science Lab Export is a leading Pulse oximeter, handheld Manufacturer,and suppliers in India, Pulse oximeter, handheld Uruguay (Montevideo), Pulse oximeter, handheld Uzbekistan (Tashkent), Pulse oximeter, handheld Venezuela (Caracas), Pulse oximeter, handheld Vietnam (Hanoi), Pulse oximeter, handheld Yemen (Sana'a), Pulse oximeter, handheld Zambia (Lusaka), Zimbabwe (Harare), Eswatini (Mbabane) (Lobamba), Ethiopia (Addis Ababa), Fiji (Suva), Gabon (Libreville), Gambia (Banjul), Georgia (Tbilisi), Ghana (Accra), India (Delhi, Mumbai, Kolkatta, Chennai), Indonesia (Jakarta), Iraq (Baghdad), Ivory Coast (Yamoussoukro), Jamaica (Kingston), Jordan (Amman), Kazakhstan (Astana), Kenya (Nairobi), Kiribati (Tarawa), Kosovo (Pristina), Kuwait (Kuwait City), Kyrgyzstan (Bishkek), Laos (Vientiane), Latvia (Riga), Lebanon (Beirut), Lesotho (Maseru), Liberia (Monrovia), Libya (Tripoli), Lithuania (Vilnuis), Luxembourg (Luxembourg), Malawi (Lilongwe), Malaysia (Federal Territory of Kuala Lumpur), Maldives (Malle), Mali (Federal Territory of Kuala Lumpur), Malta (Male), Mauritania (Nouakchott), Mauritius (Port Louis), Mexico (Mexico City), Mongolia (Ulaanbaatar), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cambodia (Phnom Penh), Cameroon (Yaoundé), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb), Cuba (Havana), Cyprus (Nicosia), Czech Republic (Prague), Denmark (Copenhagen) ,Djibouti (Djibouti City), Dominican Republic (Santo Domingo), DR Congo (Kinshasa), Ecuador (Quito), Egypt (Cairo), El Salvador (San Salvador), Equatorial Guinea (Malabo), Eritrea (Asmara), Estonia (Tallinn)

Handheld, portable, rechargeable battery powered pulse oximeter, for the noninvasive spot-checking or continuous monitoring of patient oxygen saturation (SpO2), pulse rate and respiratory rate.

Technical Specifications : 
Features :
Suitable for detection in low perfusion conditions.
Design enables use in demanding environments, e.g. shock, vibration.
Automatic correction for movement and ambient light artefacts.
Audible and visual alarms for low saturation and high/low pulse rate, thresholds settable by user.
Audible and visual alarms for sensor error or disconnected, system errors, low battery.
Alarm override and temporary silencing function.
Capable of working with, and supplied with, adult, paediatric and neonatal reusable probes.

Measurement :
SpO2 and pulse rate monitor, with plethysmography waveform, for infants, children and adults.
SpO2 detection includes the range : 70 - 100 %.
SpO2 resolution : 1 %.
SpO2 accuracy (in the range at least 70 - 100%) : ± 2% (no motion, low perfusion), ± 3% (motion) for all patients (infants, children, adults).
Pulse Rate detection range : 25 - 240 bpm.
Pulse Rate resolution : 1 bpm.
Pulse Rate accuracy : within ± 3 bpm, ± 5 bpm (motion) for all patients (infants, children, adults).
Respiratory rate range : 4 to 70 rpm
Respiratory rate resolution : 1 rpm
Respiratory rate accuracy : within ± 3 rpm A(RMS), ± 1 rpm mean error

Display :
Data display refresh rate : every 1 s
Display with main parameters : %SpO2, pulse rate, respiratory rate, signal quality, status messages, battery state indication.

Electrical characteristics :
Operated by rechargeable, non-replaceable Li-ion battery power supply.
External AC battery charger, plug style and voltage as per local supply.
Protection against defibrillator discharges.
Suitable for operating by mains power and by battery.
Automatic switch between battery and mains powered modes.
The display shows which power source is in use.
Running time on battery only ≥ 12 hours.

Casing :
Case and reusable probe suitable for cleaning and disinfection with hospital-grade cleaning products.
Overall device and probe weight < 300 g.

   

Office Address

Kunj Vihar Behind B.D. Floor Mill,
Ambala Cantt, Haryana 133001

[email protected]

+91-74543-39242

Follow Us