Science Lab Export is a leading Electrocardiograph (ECG) digital monitor and recorder Manufacturer,and suppliers in India, Electrocardiograph (ECG) digital monitor and recorder Uruguay (Montevideo), Electrocardiograph (ECG) digital monitor and recorder Uzbekistan (Tashkent), Electrocardiograph (ECG) digital monitor and recorder Venezuela (Caracas), Electrocardiograph (ECG) digital monitor and recorder Vietnam (Hanoi), Electrocardiograph (ECG) digital monitor and recorder Yemen (Sana'a), Electrocardiograph (ECG) digital monitor and recorder Zambia (Lusaka), Zimbabwe (Harare), Eswatini (Mbabane) (Lobamba), Ethiopia (Addis Ababa), Fiji (Suva), Gabon (Libreville), Gambia (Banjul), Georgia (Tbilisi), Ghana (Accra), India (Delhi, Mumbai, Kolkatta, Chennai), Indonesia (Jakarta), Iraq (Baghdad), Ivory Coast (Yamoussoukro), Jamaica (Kingston), Jordan (Amman), Kazakhstan (Astana), Kenya (Nairobi), Kiribati (Tarawa), Kosovo (Pristina), Kuwait (Kuwait City), Kyrgyzstan (Bishkek), Laos (Vientiane), Latvia (Riga), Lebanon (Beirut), Lesotho (Maseru), Liberia (Monrovia), Libya (Tripoli), Lithuania (Vilnuis), Luxembourg (Luxembourg), Malawi (Lilongwe), Malaysia (Federal Territory of Kuala Lumpur), Maldives (Malle), Mali (Federal Territory of Kuala Lumpur), Malta (Male), Mauritania (Nouakchott), Mauritius (Port Louis), Mexico (Mexico City), Mongolia (Ulaanbaatar), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cambodia (Phnom Penh), Cameroon (Yaoundé), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb), Cuba (Havana), Cyprus (Nicosia), Czech Republic (Prague), Denmark (Copenhagen) ,Djibouti (Djibouti City), Dominican Republic (Santo Domingo), DR Congo (Kinshasa), Ecuador (Quito), Egypt (Cairo), El Salvador (San Salvador), Equatorial Guinea (Malabo), Eritrea (Asmara), Estonia (Tallinn)

Technical Specifications : 
ECG analysis and full interpretation (rhythm and events), real-time and manual interpretation.
Three (3) or more recording channels.

Power Provisions : 
Built-in rechargeable lithium-ion battery.
Minimum battery operating time is 100 ECG exams or 4 hours of continuous recording.
Automatic switch to battery in case of power failure, automatic recharge on connection to mains.
Maximum battery charging time to full charge is 8 hours.
Power requirements: 100 - 240 Volts - 50/60 Hz.
Designed for frequent and easy dismount and disinfection with hospital-grade products.

Signal Acquisition : 
Input impedance > 50 MΩ.
Internal noise level < 12.5 µV peak-to-peak.
Automatic baseline centring.
Defibrillation fluctuation/overload protection.
Baseline recovery < 5 s after defibrillation.
AC fluctuation protection.
Simultaneous 12 lead acquisition ( aVR, aVL, aVF, I, II, III and V1 - V6) derived from 10 electrodes (RA, LA, RL, LL, V1 - V6).
Arrythmia and ST elevation detection.
Minimum gain/sensitivity settings include 2.5, 5, 10 and 20 mm/mV.
Lead switching, either manual, automatic or both.
Adjustable trace speeds include 5, 10 (and/or 12.5), 25 and 50 mm/s.
Minimum HR range 30 – 300 bpm with rhythm analysis.
Minimum guaranteed diagnostic frequency response of 0.05 – 150 Hz.
Common Mode Rejection Ratio (CMRR) at 60 Hz > 105 dB or better.
Calibration signal of 1 mV, manual and/or automatic.
Selectable/adjustable filters for baseline drift, muscle artefacts, mains power.
Pacemaker detection.
Accuracy of input signal reproduction ± 5 % or ± 40 μV, whichever is greater.

Recorded and Printer : 
Minimum of 3 recording channels.
Recorder display includes date/time, patient data and heart rate and basic settings.
Capable of displaying one group of at least three channels simultaneously.
Recorder waveform display includes lead marker and timing marker.
Integrated/built-in printer.
Capable of printing user selected number of channels.
Capable of printing one group of at least three channels simultaneously.
Paper speeds include 5, 10 (or 12.5), 25 and 50 mm/s.
Compatible with Z-fold paper and optionally with roll paper also (indicate compatibility).

Data Input/output, Storage and alarms 
Integrated alpha-numeric keyboard.
Patient data input fields include name, age, height and weight, gender.
Backlit Liquid Crystal Display (LCD) display screen, minimum of 12.7 cm (5 inches) diagonally.
Capable of internally storing a minimum of 10 waveforms for later retrieval, printing and/or transmission.
Expandable storage for additional waveforms if required, via USB.
Capable of exporting waveform data and reports, via USB or LAN.
Visual alarms for patient connection (lead faults), heart rate, printer and paper errors, and system errors.
Automatic self-test at start up.

   